Habitat and Long Habitat
Technical Specifications
Mainframe Material
Material*
6063 T5 Aluminum **
Mainframe Structural
1.5" x 1.0" (3.8 cm x 2.5 cm)
Component Dimension
cross section by length 0.065" (1.65 mm) wall thickness
* includes mainframe,
eave bars, base bars, weather/chimney cap and door
** aluminum is extruded,
tempered and anodized
|

Click to Enlarge
|
Roof / Sidewalls
Material
* Density: 14 oz/sqyd (475 g/sqm)
Tensile Grab:
220 lb/in (w) x 195 lb/in (f) (90 kg x 86 kg)
ASTM D1117
Trapezoid Tear:
65 lb (w) x 45 lb (f) (36 kg x 22 kg) ASTM D751
Adhesion:
25 lb/in (6.25 kg/cm)
Flame Resistance:
Method U.L. 214 - PASS Federal ASTM
specification
Fire Retardency:
PASS ASTM E84/NFPA701 Test 2/ULC S109 -
M87 large and small scale/CA1237.
1 small scale/FMVSS302
Colour: Desert
Sand, unless otherwise specified
Eave Overhang:
4 in (10 cm)
Storm Skirt:
10 in (25 cm)
Standard Window Dimension:
36 in x 36 in (92 cm x 92 cm) |

Click to Enlarge
|
Cover
Fastening System utilizes hook and loop velcro style fastener material.
Shear Strength:
1.4 kg/sqcm
* vinyl
coated polyester, waterproof, cold resistant to -35°C (cold crack 1/8
mandrel) & Ultraviolet (UV) protected
Insulation
Insulation
Material utilizes single layer air bubble pack c/w aluminum foil skin
Nominal Thickness
1/8" (0.156)
Weight
0.75 oz. per square foot
Tensile Strength >
3.5 N/mm
Temperature Range
- 60°F to +180°F
Flame Spread
20 (tested to Federal ASTM standard)
Smoke Development
5 (tested to Federal ASTM standard) |

Click to Enlarge
|
Smoke Density:
30 (tested to Federal ASTM standard)
Perm Rating:
0.000 (no vapour transmission)
Puncture Resistance:
60 Ib. per square inch
Ozone Depleting Rates:
none
Toxicity:
none
Reflectivity:
94% to 97%
Pliability:
No cracking when bent over a 5mm mandrel at -10°C
Emmitance:
0.03
Mold and Mildew:
none
R-Factor:
~3
1st Layer 0.00035
mils of 99% pure aluminum foil
2nd Layer 0.002 mils of linear
low density polyethylene backing
3rd Layer 0.0025 mils of
polyethylene bubble
4th Layer 0.002 mils of linear
low density polyethylene backing
5th Layer 0.00035 mils of
99% pure aluminum foil
|
Warranty
Design Shelter
Systems offers a 365-day warranty on any parts or components found to
be defective from delivery date (indicated on final invoice).
Defective components will be provided to field locations at no charge
FOB Mississauga, Canada. Field labour is not included.
Alternatively,
damaged frames and/or covers can be returned to our factory for repair.
Shipping charges to and from customer destination are extra.
|
Maintenance
Cover Maintenance:
Particular attention should be given to keeping the velcro as clean
as possible. Periodic brushing of the velcro fastener will extend
the life of the product. Cover material can be easily cleaned
using mild soap and water. Periodic wiping down of the cover is
recommended to maximize the life of the product.
Frame
Maintenance: Particular attention should be placed on keeping folding
and telescopic components free from dirt, grass and debris. Periodic
wiping down of the frame and clearing of the components is recommended
to maximize the life of the product.
|